Heat pump connected directly to the heating system with 3wv for domestic hot water (dhw) preparation. Verified on/off solution since 2007 with continuous technical upgrades.
Features
- Use for heating and cooling
- The temperature of heating water to 55 °C
- Ecological refrigerant R407C
- Temperatures range from +30°C to -20°C
- Outdoor compact
- Very easy installation, quiet operation
- Control up to 6 heating circuits

Standard equipment
- Graphic terminal PGD
- Low-noise EC fan
- Equitherm control system MaR Carel
- Built-in immersion heater and circulation pump
- Electronically controlled coolant injection
- Control of three heating circuits (1x hot water +2x heating water)
Downloads
Download EU Regulations
No. 811/2013 and No. 813/2013 – parameters:
Options
- Internet HP control
- Full Cooling reversing
- Terminal pAD temperature compensation
- Terminal pADh floor cooling
- Three phase relay
- Softstart
- Expanded control module
- RAL code colours on demand
- Silver, red or green colour
Models
- BoxAir-22Z (8,2 kW, A7W35, A+, COP 4,4)
- BoxAir-26Z (10,6 kW, A7W35, A+, COP 4,2)
- BoxAir-30Z (12,2 kW, A7W35, A+, COP 4,3)
- BoxAir-37Z (15,4 kW, A7W35, A+, COP 4,5)
- BoxAir-45Z (18,2 kW, A7W35, A++, COP 4,5)

![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |